News detail
NewsCurrent position > News detail

V-cone flowmeter model | Scope of application of V-cone flowmeter

『V-cone flowmeter model』Related information(clamp on meter|electromagnetic meter|venturi meterrotameter|orifice meter|ultrasonic flow meter|mass flow meter|coriolis mass flow meter|coriolis flow meter|magnetic flow meter|magmeter flow meter|magflow flow meter|mag meter flow meter|electromagnetic flow meter|vortex flow meter|turbine flow meter|thermal mass flow meter|thermal flow meter|rotameter flow meter)

1. Schematic diagram of V-cone flowmeter

nominal diameter: Φ 15- Φ 2000 measuring medium: liquid, gas, steam measuring medium temperature range: -200 ℃~+800 ℃ pressure level: dispersion 1.0MPa~10.5MPa accuracy level: 0.5 level, 1.0 level, 1.5 level, 2.5 level body material: cone material is stainless steel, pipeline and flange are carbon steel. (Other material agreement supply) β value range: 0.45... 0.85 nominal diameter: Φ 80- Φ 2000 measuring medium: liquid, gas, steam measuring medium temperature range: -200 ℃~+800 ℃ pressure level: 1.0MPa~10.5MPa accuracy level: 0.5, 1, 1.5, 2.5 table body material stool: cone material is stainless steel, pipeline, flange is carbon steel (other material agreement supply) β value range: 0.45... 0.85 nominal diameter: Φ 15- Φ 2000 measuring medium: liquid, gas, steam measuring medium temperature grinding range: -200 ℃~+800 ℃ pressure level

1.0MPa~10.5MPa accuracy level: 0.5, 1, 1.5 and 2.5 grade body materials: The cone material is stainless steel, and the pipes and flanges are mad

V-cone flowmeter model
e of carbon (other materials are supplied according to the agreement). β value range: 0.45... 0.85

2. The applicable range of V-cone flow meters

1、 Nominal diameter: 15mm ≤ DN ≤ 1800mm

2. Nominal pressure: PN ≤ 40MPa

3. Reynolds number range: 5 × 10 ≤ ReD ≤ 10

4. Accuracy level: 0.5 level, 1 level

5. Length of straight pipe section: front 1-3D, back 0-1D

6. Suitable media: gas, liquid, steam and other noisy media

7. Aperture ratio: β=0.3-0.75

8. Maximum temperature: 540 ℃

9. Repeatability accuracy

: ± 0.1%

10. Range ratio: 15:11

1. Wide range of β values: The unique geometric shape of the V-cone flow sensor allows for a wide range of β values; 1

2、 Wide caliber range: DN25 to DN2000; 1

3、 Accuracy level: 0.5 level (the accuracy of differential pressure flow transmitter should be higher than 0.2 level, including 0.2 level), (β: 0.45-0.85, when β<0.55, the accuracy level is ≤ 0.30 when the range ratio is 4:1)

3. Radar type flowmeter

『SILVER Official Website SERVICE』

Copyright2026SILVER E-Commerce
+86 15365082610